Jun 24, 2019 learn how labview can help you control and automate your agilent 34970a. Publication number 3321090001 copyright 2008 agilent. The agilent technologies 34970a34972a combines precision. Software and technical data rights granted to the federal government include only those rights customarily provided to end user customers. The schematics for the 34970a are available as a separate downloadable pdf file from the agilent web site at agilent 34970a data acquistion switch unit note. Included runtime software components included in the download. Its a data logger configured with a 20channel relay multiplexer, the 34970a34972a becomes a powerful, lowcost data logger for simple characterization applications. The table below shows the general environmental requirements for this instrument. We have 4 agilent technologies 34970a manuals available for free pdf download. Three module slots are built into the rear of the instrument to accept any combination of data acquisition or switching modules. View and download agilent technologies 34970a manual online. Data loggers, or data recorders, collect information over time for a variety of purposes. Control the missing user guide updated 091515 apple, ipad, iphone, and. Agilent 34970a 34972a data acquisitionswitch unit note.
Keysight benchlink data logger pro software for the 34970a34972a provides a convenient way to collect and analyze your data. Agilent e4866a service manual, user manual language. Use them to route test signals between your device under test and your signal generator, oscilloscope, spectrum analyzer, or other instrumentation. Keysight 34970a34972a data acquisition switch unit. Hp agilent test equipment pdf manuals cd downloads. Use them to route test signals between your device. Note that this model does not have the bumper kit and handle installed. Agilent 34970a data acquisition switch unit user manual. Operating manual analog programmable dc power supplies agilent technologies series 654xa, 655xa, 657xa sa agilent part no. Agilent hp 4934a transmission impairment measuring set. Agilent 6460 user manual this manual features sample preparation methods using agilent s bond elut designed for chromatographers, these ph meters offer intuitive user the agilent 6460 triple quadrupole.
Agilent hp 34970a data acquisition switch unit w 3 cards. Switch agilent technologies 34970a quick reference manual 21 pages. A data logger uses internal memory and sensors to gather and document. Agilent 8163ab lightwave multimeter, agilent 8164ab. The keysight 34970a data acquisition data logger switch consists of a threeslot mainframe with a builtin 6 12 digit digital multimeter.
Software and technical data rights granted to the federal government include only those rights customarily provided. If memory serves, this model has been around for awhile, so your chances are pretty good that it will be available. You are covered by the ebay money back guarantee if you receive an item that is not as described in the listing. Agilent and the user have a separate written agreement with warranty. Jun 12, 20 agilent 34970a errors and battery replacement page 1 eevblog electronics community forum. Agilent 6460 user manual this manual features sample preparation methods using agilents bond elut designed for chromatographers, these ph meters offer intuitive user the agilent 6460 triple quadrupole. Agilent s former test and measurement business has become keysight technologies. Benchlink data logger pro software download for 34970a and 34980a. Benchlink data logger pro software for keysight 34970a. Agilent technologies 34970a manuals manuals and user guides for agilent technologies 34970a. Operating manual analog programmable dc power supplies. The software is a windows based application that uses a familiar spreadsheet environment to define measurement data to be collected.
Whats more, the 34972a with its lan and usb interfaces is ideal for. Users guide software overview guide performance verification manual online information system in this book. Each channel can be configured independently to measure one of 11. Agilent 34970a34972a data acquisitionswitch unit note. Agilent technologies 34972a user manual pdf download. Agilent 34830a benchlink data logger pro software for. They have many service manuals available for free download. Im doing scanningsover 4 channels 10k thermistors with scan to scan interval of 0,01secs0,001 secs. From the products proven 150,000 hour mean time between failure, to its standard 1year warranty, agilent stands behind you to bring a new level of confidence to your lowlevel measurements. View and download agilent technologies 34972a user manual online. View and download agilent technologies 34970a quick reference manual online. Our goal is to connect the laptop to the agilent 34970a with an rs232 to usb adapter for agilent instruments with laptop pcs running any microsoft os.
Quick start 1 keysight 34970a 34972a user s guide 51 1 remove the power cord. National instruments provides a free labview instrument driver for the 34970a, which gives you programmatic control. Rf multiplexers offer broadband switching capabilities for highfrequency and pulsed signals. Instrument state storage with userdefined names portable, ruggedized case with nonskid feet. Using the agilent 34970a with labview national instruments.
Delivery method can be selected during checkout from our online store. This document contains references to agilent technologies. Programming 34970a for high channel count and high throughput. For more information on using the 34970a for data logging applications, see page 6. The agilent technologies 34970a34972a combines precision measurement capability with flexible signal connections for your production and development test systems. The schematics for the 34970a are available as a separate downloadable pdf file from the agilent web site at. I dont have a you need the frequencies stated in the manual. We have a dell precision m90 laptop running windows 7 professional, 32 bit, intel centrino duo, and usb serial ports. The agilent hp 4934a transmission impairment measuring set increases installation and maintenance productivity for telephone companies and service providers through its ease of use, portability, and. Fixes a defect in the 64bit driver where the modulepath64 field was empty 64bit ivic class compliant calls should now work. Agilent 34970a errors and battery replacement page 1 eevblog electronics community forum.
The examples included use the agilent io objects in ms visual basic 6. Remove the fuseholder assembly from the rear panel. Our goal is to connect the laptop to the agilent 34970a with an rs232 to. Agilent technologies 34970a quick reference manual. Page 16 agilent 34901a 20channel multiplexer see page 164 in the user s guide agilent 34902a 16channel multiplexer.
Get free access to pdf agilent 34970a user manual at our ebook library glad to know that right now agilent 34970a user manual pdf is available on our. Gpib dc power supplies agilent technologies models 664xa, 665xa, 667xa, and 668xa. The procedures in this manual are intended for use by qualified, servicetrained personnel only. The keysight agilenthp 34970a data acquisition data logger switch unit consists of a threeslot mainframe with a builtin 6 12 digit digital multimeter. Refer to manual for additional safety information dl3 getting started. Page 1 agilent 34970a data acquisitionswitch unit product overview agilent performance at a fraction of the cost of other standalone data acquisition systems. Page 6 the agilent 34970a is easy to use for a multitude of data logging and monitoring applications, either standalone or with a computer. Rapid assessment key user manual table of contents getting started with the. Each channel can be configured independently to measure one of 11 different functions without the added cost or hassles of signalconditioning accessories. Reproduced with permission, courtesy of agilent technologies inc. Agilent technologies 34970a quick reference manual pdf. For more information on using the 34970a for data logging. Use the software to set up your test, acquire and archive measurement data, and perform realtime display and analysis of your incoming measurements.
If it doesnt but does show an other devices selection, click on that and search for a driver. Agilent 34970a errors and battery replacement page 1. Labview is an industrystandard graphical programming environment that can be used to quickly and easily acquire, analyze, and present data from the 34970a. Step format 3d model of the 34970a data acquisition data logger switch unit with modules installed. Keysight 34970a34972a over a remote interface using the programming language. The agilent technologies 34970a 34972a combines precision measurement capability with flexible signal connections for your production and development test systems. For more information, go to this help file contains reference information to help you program the keysight 34970a 34972a over a remote interface using the programming language. Agilent benchlink data logger is a windowsbased application designed to make it easy to use the 34970a with your pc for gathering and analyzing measurements. Its a data logger configured with a 20channel relay multiplexer, the 34970a34972a. User manual, service manual, manual, quick reference manual. Unless otherwise indicated, this manual applies to all serial numbers. Apr 18, 20 if it doesnt but does show an other devices selection, click on that and search for a driver.
Creating datalogging applications in microsoft excel pdf free. Agilent 34830a benchlink data logger pro software for agilent 34970a data sheet based on prede. Hp agilent pdf manuals cd downloadable manuals for test equipment. Its flexible, modu lar design makes it scalable from 20 to 120 chan nels, and lets you add actuator, digital io, and analog output channels for simple control. Agilent provides this customary commercial license in software and technical data pursuant to far 12. The agilent 34970a consists of a threeslot mainframe with a builtin 6 12 digit digital multimeter option 001, removes the dmm. The calibration procedure is in the service manual. Agilent performance at a fraction of the cost of other. Each hplc module is supplied with a reference manual which describes installation, troubleshooting, repair, parts and theory of operation. Pdf on mar 23, 20, rajkumar viral and others published development of an. Keysight 34970a data acquisitionswitch unit family tme electronic. The problem is that the readings arent stable at all and thefluctuations depend on range and resolution.